Skip to content

Latest commit

 

History

History
44 lines (37 loc) · 2.95 KB

File metadata and controls

44 lines (37 loc) · 2.95 KB

Tested Configurations

This matrix records explicit evidence. It is not a vendor-certification claim.

Area Configuration Evidence level Status
Build Windows windows-latest, .NET 8 SDK GitHub Actions build/test Automated
Parser Golden SV frames and malformed BER cases xUnit regression tests Automated
Runtime stability Eight interleaved SV streams, exact 2/4/8-cycle windows, 65536 rollover, duplicate/gap handling, concurrent snapshot reads Repeated RuntimeStability xUnit category with TRX artifacts Automated
Runtime snapshot Copied selected-stream identity, waveform, analog, phasor, shape, and diagnostics; atomic generation publication Repeated RuntimeArchitecture xUnit category with TRX artifacts Automated
Classic PCAP replay PCAP 2.4, Ethernet link type 1, little/big endian, micro/nanosecond timestamps, truncated/oversized rejection Repeated RuntimeArchitecture xUnit category with TRX artifacts Automated
Replay isolation Three interleaved SV streams replayed through the live raw analyzer entry point Runtime architecture regression tests Automated
Packaging Windows x64 self-contained single-file ZIP Candidate/release workflow and package verification script Automated
Website Static GitHub Pages source validation Pages workflow Automated
Live capture Windows + Npcap + selected Ethernet adapter Maintainer smoke/soak evidence Maintainer validation
Runtime soak 60-minute live session, three simultaneous streams, memory 141.6 MB start / 144.5 MB peak / 142.1 MB end, zero freeze/disconnect/cross-stream mixing V1.3.0_BETA2_FIELD_EVIDENCE.md PASS
Timing Windows/Npcap or recorded PCAP timestamps Screening only Not measurement-grade
PCAPNG replay Not implemented in v1.4.0-beta.1 No evidence Not claimed
Multi-vendor SCL SCD/ICD/CID examples and parser tests Partial Broader validation required
Hardware timestamping Validated NIC/TAP timestamp path None in public beta Not claimed

Release evidence to record

For each public beta, record:

  • Windows build used
  • Npcap version
  • adapter/capture-path or replay-source type
  • publisher or sanitized replay source
  • replay file format, link type, timestamp resolution, and endian variant
  • SV rates and timebases exercised
  • multi-stream count
  • harmonic/shape scenarios
  • 4000 and 65536 rollover behavior
  • duplicate/gap/restart behavior
  • duration of soak test
  • memory start/peak/end observations
  • UI freeze, disconnect, and stream cross-contamination counts
  • immutable runtime generation and replay regression results
  • known limitations

Use V1.3.0_BETA2_FIELD_EVIDENCE.md for the maintained 60-minute live stability baseline. Add a new sanitized record when v1.4 replay is validated with a real field capture.

Sanitize all project, device, MAC/IP, site, customer, SCL, and capture identifiers before publishing evidence.