You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This PR updates FT0 and FV0 digitizer settings for Run 3 data (runs 562260–568721) to better reflect 2025 conditions and recent digitizer improvements.
Key changes
FT0 calibration: set to ~14 ADC/MIP (mMip_in_V = 7, updated conversion factors)
System-dependent tuning:
Pb–Pb: DCS-consistent FT0 thresholds and FV0 charge settings adapted to high multiplicity
pp / OO / NeNe: DCS-consistent FT0 thresholds and FV0 charge levels for low-multiplicity systems
FV0 ADC/MIP:
REQUEST FOR PRODUCTION RELEASES:
To request your PR to be included in production software, please add the corresponding labels called "async-" to your PR. Add the labels directly (if you have the permissions) or add a comment of the form (note that labels are separated by a ",")
+async-label <label1>, <label2>, !<label3> ...
This will add <label1> and <label2> and removes <label3>.
The following labels are available
async-2023-pbpb-apass4
async-2023-pp-apass4
async-2024-pp-apass1
async-2022-pp-apass7
async-2024-pp-cpass0
async-2024-PbPb-apass1
async-2024-ppRef-apass1
async-2024-PbPb-apass2
async-2023-PbPb-apass5
@f3sch : It appears the ITS-MFT staggering development c9acd57adde in O2 breaks the O2DPG CI. The log says
3-[INFO] Init CcdApi with UserAgentID: o2-qc/o2-qc@12274 target/Linux_x86_64 init/1776652701146 id/mesosdaq@alimetal04.cern.ch session/YKqYhHT0, Host: http://alice-ccdb.cern.ch/(cache snapshots to dir=/sw/BUILD/f0a243902a4ac12198ccc818e8513d6b5b5273dc/O2DPG-sim-tests/o2dpg-sim_tests/o2dpg_tests/anchored/88_test_anchor_2023_apass2_pp.sh_dir/ccdb, prefer if available), Curl timeouts: upload:20 download:5
4-[INFO] CCDB Time-machine constrained detected. Setting condition-not-after constrained to timestamp 3385078236000
5-For later analysis we write a core dump to core_dump_12273
6:[FATAL] error while setting up workflow in o2-global-track-cluster-reader: missing option: enable-mft-staggering (No such node (enable-mft-staggering))
7-[ERROR] invalid workflow in o2-qc: No matching output found for <matcher query: (and origin:MFT (and description:CLUSTERSROF (and subSpec:0 (just startTime:$0 ))))> as requested by data processor "qc-task-MFT-Clusters". Candidates:
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
This PR updates FT0 and FV0 digitizer settings for Run 3 data (runs 562260–568721) to better reflect 2025 conditions and recent digitizer improvements.
Key changes
FT0 calibration: set to ~14 ADC/MIP (mMip_in_V = 7, updated conversion factors)
System-dependent tuning:
FV0 ADC/MIP: